Special Transformer

Special Transformer
We are capable of manufacturing various types of special transformers such as Traction Transformers, Rectifier Transformers, Moveable Transformers, and Electric Furnace Transformers to meet differ
+86 18168856542
+86 18168856542
rena@wxqysteel.com

Product Description


Project DimensionStandard/General Transformer IntroductionSpecial Transformer IntroductionCustomizable & Special Solutions
Core OverviewUses insulating oil for heat dissipation and insulation. It is the most mature, reliable and widely used power distribution equipment in power grids.Designed for specific industrial processes, special voltage/waveform requirements or extreme environments, not for standard power distribution. Core advantage is to achieve specialized electrical and physical characteristics that general transformers cannot provide.Provide full-process customization from conceptual design to prototype manufacturing, serving as a problem-oriented engineering solution.
Rated CapacityCommon range: 30kVA to 20MVA or higherCustomized based on special application scenarios (e.g., small capacity for testing transformers, large capacity for electric furnace transformers)Non-standard capacity customization can be carried out according to load calculation for both standard and special transformers
Voltage ClassPrimary side: 10kV, 11kV, 35kV, etc.; Secondary side: 0.4kV, 6.3kV, etc.Customized according to application scenarios (e.g., low voltage for electric furnace transformers, high voltage for testing transformers)Supports voltage design conforming to any global standard, meeting the requirements of special input-output voltage ratio
Frequency50Hz or 60Hz50Hz/60Hz or special frequency for testing scenariosCan be designed as 50/60Hz universal type or adapted to specific frequency requirements
Phase NumberThree-phase (mainstream), single-phaseSingle-phase, three-phase or special phase combination based on application needsProvides single-phase, three-phase or special phase combination transformers
Connection GroupCommon groups such as Dyn11, Yyn0, YNd11, etc.Customized according to special load characteristicsAny connection group can be customized according to system grounding mode, harmonic suppression and other requirements
Performance and LossComplies with IEC standards and provides different energy efficiency levels (e.g., S11, S13)High short-circuit impedance for electric furnace transformers; pure waveform for testing transformersOptimize design to achieve specific energy efficiency levels (e.g., meeting China's Level 1 energy efficiency) and pursue lower no-load and load losses
Winding MaterialElectrolytic copper (mainstream) or electrical aluminum (lower cost)High-conductivity electrolytic copper is preferred for special transformersOptional according to performance and cost budget, and can specify conductor purity or special alloys
Core MaterialHigh-quality cold-rolled grain-oriented silicon steel sheetAmorphous alloy core for dry-type special transformers (e.g., dry-type amorphous alloy transformers)Can be upgraded to high magnetic permeability silicon steel or amorphous alloy core, greatly reducing no-load loss
Cooling MethodOil-immersed self-cooled (ONAN) is the most commonCompact cooling structure for traction transformers; efficient cooling for electric furnace transformersCan customize enhanced cooling methods such as oil-immersed air-cooled (ONAF) and forced oil circulation air-cooled (OFAF) according to heat dissipation needs
Tank StructureStandard corrugated or finned tankExplosion-proof tank for mine transformers; compact tank for traction transformersCustomizable fully sealed type (maintenance-free), type with expander, or special shape to meet space constraints; provide flameproof or increased-safety enclosures for mine transformers
Outlet MethodStandard bushing outletCustomized outlet interface for special application scenarios (e.g., short-network interface for electric furnace transformers)Can customize cable box outlet, busbar bridge connection, or American/European prefabricated interface; customize short-network interface according to furnace type and metallurgical process
Protection LevelOutdoor design, usually IP23IP55+ for offshore wind power and mine transformersCan be customized up to IP55 and above for occasions with extremely high dust and waterproof requirements
Climate ProtectionSuitable for general outdoor environmentSalt spray resistance for offshore wind power transformers; wind and sand resistance for plateau transformers; mold resistance for humid environment transformersSpecial treatments such as wind and sand resistance, salt spray resistance (for coastal areas), mold resistance (for hot and humid areas), plateau type (for high-altitude areas), etc.
Fire Protection RequirementsUses mineral insulating oilMineral insulating oil or high ignition point synthetic resin insulating oil according to scenariosCan be filled with high ignition point synthetic resin insulating oil to meet higher fire safety standards
Environmental Protection RequirementsStandard mineral oil is recyclableDry-type structure for special transformers to meet environmental protection requirements; biodegradable natural ester insulating oil optionalProvides transformers with biodegradable natural ester insulating oil to meet the most stringent environmental protection requirements
Certification and StandardsComplies with IEC standards and routine factory testsComplies with industry-specific standards (e.g., IEEE Std 387 for nuclear power plant transformers, GB3836/ATEX for mine explosion-proof transformers)Can obtain specific national certifications (e.g., UL, CE, CSA, GOST-R) according to the target market; assist in obtaining classification society certifications (CCS, DNV, ABS, etc.), military standards (MIL) and nuclear power quality assurance system (QA)
Special Application Classification-1. Electric Furnace Transformer: Used for arc furnaces, submerged arc furnaces and resistance furnaces2. Rectifier Transformer: Matched with rectifiers for electrolytic chemical industry, rail transit traction3. Traction Transformer: Used for electric locomotives, high-speed railways and urban rail transit4. Testing Transformer: Used for equipment insulation withstand voltage tests5. Others: Phase-shifting transformer, grounding transformer, frequency conversion transformer, etc.1. Customize electric furnace transformer parameters according to furnace type and metallurgical process2. Customize rectifier transformer with multi-pulse design to suppress harmonics3. Customize traction transformer complying with EN/IEC railway standards4. Customize cascade-type/gas-filled testing transformer for ultra-high voltage scenarios
Special Function Classification-1. On-load Tap-changer Transformer: Adjust voltage ratio during load operation2. Split Transformer: Split low-voltage winding to limit short-circuit current3. Dry-type Amorphous Alloy Transformer: Ultra-low no-load loss (60%-70% lower than silicon steel dry-type transformers)1. Customize voltage regulation range (e.g., ±10%) and levels (e.g., 9 levels, 17 levels) for on-load tap-changer transformers2. Customize split impedance and number of branches for split transformers3. Provide top-level energy-saving solutions for data centers and green buildings with dry-type amorphous alloy transformers
Extreme Environment Adaptation-1. Nuclear Power Plant Transformer: High reliability and seismic resistance2. Offshore Wind Power Transformer: Resistant to salt spray corrosion and frequent start-stop3. Mine Explosion-proof Transformer: Explosion-proof and flame-retardant1. Design nuclear power plant transformers according to nuclear safety classes (K1/K2/K3) and conduct LOCA test2. Customize compact, high anti-corrosion grade offshore wind power transformers integrated with converters3. Provide explosion-proof treated mine transformers complying with GB3836/ATEX standards
Intelligent MonitoringBasic state monitoringBasic state monitoring for special transformersIntegrate advanced diagnostic systems such as optical fiber temperature measurement, on-line dissolved gas analysis (DGA), vibration analysis and partial discharge monitoring, and provide predictive maintenance platform interfaces
Logistics SolutionStandard transportationSpecial transportation for oversized/overweight special transformersProvide complete logistics solutions such as split transportation with on-site assembly, detachable radiators and nitrogen-filled transportation for ultra-large capacity transformers

Factory Display

  • 202503201803225644
  • 1769419917382
  • 202503201803470398
  • 202503201804224119
  • 1769419002085
  • 1769419019344
  • 1769419157300
  • 202503201804205348

Certificate Display

1769419326647

Packaging And Transportation

  • 1769413575789
  • 1769413556401
  • 1769415245649
  • 1769410152341
  • 1769410274525
  • 1769410182615
  • 1769418399518
  • 1769418798682

Contact Us

Submit

Core Competencies

Full-chain product manufacturing expert
We focus on the core physical carriers of power transmission. Our main business covers: transformer series and power tower series.

A Manufacturing System Centered on Technology and Quality

Technology-Driven: We have a professional R&D and engineering team.

Quality Foundation: The company has established a comprehensive quality control system covering the entire process from raw material procurement and production to finished product delivery.

Intelligent Manufacturing: We have achieved high-efficiency, high-consistency, large-scale production.

Globalized Services and Project Delivery

We deeply understand and meet the complex needs of different regions and standards, providing full-process service support from technical consultation, drawing design, manufacturing to logistics and installation guidance to ensure smooth project delivery.